Run10013 Wed Aug 2 04:59:09 2000 Momentum 148 GeV, particle type: 1 Xcal= 79.0 Ycal= 88.0 10000 Events written to file data/run_10013.dat Pattern unit statistics: 15/15 pi/e*C Trig 9973 16/15 VM 12 c low 0 15/14 pi/e Trig 43 16/14 VM 11 left 0 15/13 S random Tr 0 16/13 VM 10 0 15/12 mu Trig 7 16/12 VM 9 0 15/11 MWPC Trig 0 16/11 VM 8 1 15/10 VM hole low 5 16/10 VM 7 1 15/9 pi/e/mu 9985 16/9 VM 6 cent up 0 15/8 0 16/8 VM 5 1 15/7 C1 8 major. 4289 16/7 VM 4 0 15/6 C1 7 major. 8663 16/6 VM 3 0 15/5 C1 6 major. 9981 16/5 VM 2 0 15/4 Early Pile up 315 16/4 VM 1 right 0 15/3 H Random Trig 13 16/3 M1 10 left 0 15/2 F pretrigger 9985 16/2 M1 9 44 15/1 VM hole up 7 16/1 M1 8 77 15/0 all events 10000 16/0 M1 7 112 17/15 M1 6 234 18/15 0 17/14 M1 5 3 18/14 0 17/13 M1 4 1 18/13 0 17/12 M1 3 2 18/12 0 17/11 M1 2 0 18/11 0 17/10 M1 1 right 0 18/10 0 17/9 M2 10 left 0 18/9 0 17/8 M2 9 0 18/8 0 17/7 M2 8 1 18/7 0 17/6 M2 7 6 18/6 0 17/5 M2 6 220 18/5 0 17/4 M2 5 24 18/4 0 17/3 M2 4 15 18/3 0 17/2 M2 3 12 18/2 0 17/1 M2 2 0 18/1 0 17/0 M2 1 0 18/0 Late pile up 51 ************************************************* Number of signal Hits on any MWPC 47455 Events used to calculate efficiencies 9987 Effciciency of MWPC 2 in X is 87.4 % in Y is 93.9 % Effciciency of MWPC 3 in X is 93.4 % in Y is 88.1 % Effciciency of MWPC 4 in X is 92.5 % in Y is 94.5 % Effciciency of MWPC 5 in X is 93.4 % in Y is 93.8 % ************************************************* ************************************************* number of physics triggers = 9618 estimated number of electrons = 7653 estimated number of pions = 1961 NOTE: these numbers only include physics triggers chosen by the shift crew (ie. e pi or mu triggers could be requested) *************************************************