Run10044 Wed Aug 2 21:54:23 2000 Momentum 150 GeV, particle type: 3 Xcal= 224.0 Ycal=-150.0 10000 Events written to file data/run_10044.dat Pattern unit statistics: 15/15 pi/e*C Trig 9988 16/15 VM 12 c low 3 15/14 pi/e Trig 45 16/14 VM 11 left 0 15/13 S random Tr 0 16/13 VM 10 0 15/12 mu Trig 2 16/12 VM 9 1 15/11 MWPC Trig 0 16/11 VM 8 1 15/10 VM hole low 2 16/10 VM 7 1 15/9 pi/e/mu 9993 16/9 VM 6 cent up 0 15/8 0 16/8 VM 5 1 15/7 C1 8 major. 4248 16/7 VM 4 1 15/6 C1 7 major. 8526 16/6 VM 3 1 15/5 C1 6 major. 9990 16/5 VM 2 0 15/4 Early Pile up 204 16/4 VM 1 right 1 15/3 H Random Trig 6 16/3 M1 10 left 1 15/2 F pretrigger 9992 16/2 M1 9 315 15/1 VM hole up 3 16/1 M1 8 564 15/0 all events 10000 16/0 M1 7 957 17/15 M1 6 1103 18/15 0 17/14 M1 5 22 18/14 0 17/13 M1 4 1 18/13 0 17/12 M1 3 4 18/12 0 17/11 M1 2 2 18/11 0 17/10 M1 1 right 1 18/10 0 17/9 M2 10 left 0 18/9 0 17/8 M2 9 0 18/8 0 17/7 M2 8 4 18/7 0 17/6 M2 7 1 18/6 0 17/5 M2 6 42 18/5 0 17/4 M2 5 4 18/4 0 17/3 M2 4 8 18/3 0 17/2 M2 3 5 18/2 0 17/1 M2 2 0 18/1 0 17/0 M2 1 0 18/0 Late pile up 28 ************************************************* Number of signal Hits on any MWPC 48460 Events used to calculate efficiencies 9994 Effciciency of MWPC 2 in X is 92.3 % in Y is 94.5 % Effciciency of MWPC 3 in X is 94.1 % in Y is 84.7 % Effciciency of MWPC 4 in X is 92.9 % in Y is 96.6 % Effciciency of MWPC 5 in X is 94.3 % in Y is 94.0 % ************************************************* ************************************************* number of physics triggers = 9760 estimated number of electrons = 964 estimated number of pions = 8796 NOTE: these numbers only include physics triggers chosen by the shift crew (ie. e pi or mu triggers could be requested) *************************************************