Run10206 Sun Aug 6 08:57:51 2000 Momentum 150 GeV, particle type: 2 Xcal= 240.0 Ycal=-140.0 10000 Events written to file data/run_10206.dat Pattern unit statistics: 15/15 pi/e*C Trig 24 16/15 VM 12 c low 3 15/14 pi/e Trig 59 16/14 VM 11 left 0 15/13 S random Tr 0 16/13 VM 10 2 15/12 mu Trig 9628 16/12 VM 9 0 15/11 MWPC Trig 0 16/11 VM 8 4 15/10 VM hole low 14 16/10 VM 7 1 15/9 pi/e/mu 9693 16/9 VM 6 cent up 0 15/8 0 16/8 VM 5 0 15/7 C1 8 major. 565 16/7 VM 4 0 15/6 C1 7 major. 2643 16/6 VM 3 1 15/5 C1 6 major. 4907 16/5 VM 2 1 15/4 Early Pile up 34 16/4 VM 1 right 0 15/3 H Random Trig 287 16/3 M1 10 left 0 15/2 F pretrigger 9692 16/2 M1 9 66 15/1 VM hole up 20 16/1 M1 8 168 15/0 all events 10000 16/0 M1 7 641 17/15 M1 6 9396 18/15 0 17/14 M1 5 17 18/14 0 17/13 M1 4 2 18/13 0 17/12 M1 3 0 18/12 0 17/11 M1 2 0 18/11 0 17/10 M1 1 right 0 18/10 0 17/9 M2 10 left 1 18/9 0 17/8 M2 9 0 18/8 0 17/7 M2 8 42 18/7 0 17/6 M2 7 142 18/6 0 17/5 M2 6 9535 18/5 0 17/4 M2 5 518 18/4 0 17/3 M2 4 96 18/3 0 17/2 M2 3 58 18/2 0 17/1 M2 2 0 18/1 0 17/0 M2 1 0 18/0 Late pile up 233 ************************************************* Number of signal Hits on any MWPC 24930 Events used to calculate efficiencies 9713 Effciciency of MWPC 2 in X is 48.2 % in Y is 50.1 % Effciciency of MWPC 3 in X is 48.7 % in Y is 44.3 % Effciciency of MWPC 4 in X is 44.9 % in Y is 49.4 % Effciciency of MWPC 5 in X is 49.4 % in Y is 49.3 % ************************************************* ************************************************* number of physics triggers = 9444 estimated number of electrons = 697 estimated number of pions = 8747 NOTE: these numbers only include physics triggers chosen by the shift crew (ie. e pi or mu triggers could be requested) *************************************************