Run10661 Fri Aug 18 08:04:25 2000 Momentum 50 GeV, particle type: 3 Xcal=-240.0 Ycal= .0 10000 Events written to file data/run_10661.dat Pattern unit statistics: 15/15 pi/e*C Trig 41 16/15 VM 12 c low 2 15/14 pi/e Trig 75 16/14 VM 11 left 0 15/13 S random Tr 0 16/13 VM 10 1 15/12 mu Trig 9598 16/12 VM 9 4 15/11 MWPC Trig 0 16/11 VM 8 5 15/10 VM hole low 20 16/10 VM 7 2 15/9 pi/e/mu 9696 16/9 VM 6 cent up 0 15/8 0 16/8 VM 5 0 15/7 C1 8 major. 2048 16/7 VM 4 0 15/6 C1 7 major. 5051 16/6 VM 3 1 15/5 C1 6 major. 6435 16/5 VM 2 0 15/4 Early Pile up 49 16/4 VM 1 right 1 15/3 H Random Trig 283 16/3 M1 10 left 1 15/2 F pretrigger 9695 16/2 M1 9 109 15/1 VM hole up 24 16/1 M1 8 249 15/0 all events 10000 16/0 M1 7 813 17/15 M1 6 9230 18/15 0 17/14 M1 5 10 18/14 0 17/13 M1 4 0 18/13 0 17/12 M1 3 0 18/12 0 17/11 M1 2 0 18/11 0 17/10 M1 1 right 0 18/10 0 17/9 M2 10 left 0 18/9 0 17/8 M2 9 0 18/8 0 17/7 M2 8 54 18/7 0 17/6 M2 7 118 18/6 0 17/5 M2 6 9550 18/5 0 17/4 M2 5 339 18/4 0 17/3 M2 4 82 18/3 0 17/2 M2 3 45 18/2 0 17/1 M2 2 0 18/1 0 17/0 M2 1 0 18/0 Late pile up 192 ************************************************* Number of signal Hits on any MWPC 27495 Events used to calculate efficiencies 9717 Effciciency of MWPC 2 in X is 54.5 % in Y is 56.1 % Effciciency of MWPC 3 in X is 55.3 % in Y is 54.0 % Effciciency of MWPC 4 in X is 52.3 % in Y is 53.7 % Effciciency of MWPC 5 in X is 54.2 % in Y is 55.2 % ************************************************* ************************************************* number of physics triggers = 9470 estimated number of electrons = 694 estimated number of pions = 8776 NOTE: these numbers only include physics triggers chosen by the shift crew (ie. e pi or mu triggers could be requested) *************************************************