Run7859 Momentum 20 GeV, particle type: 3 CryoX= 10 TableY= 0 10001 Events written to file data/run_7859.dat Pattern unit statistics: 15/15 pi/e*C Trig 8592 16/15 VM 12 c low 43 15/14 pi/e Trig 52 16/14 VM 11 left 2 15/13 S random Tr 440 16/13 VM 10 10 15/12 mu Trig 0 16/12 VM 9 30 15/11 MWPC Trig 959 16/11 VM 8 57 15/10 VM hole low 373 16/10 VM 7 84 15/9 pi/e/mu 0 16/9 VM 6 cent up 4 15/8 0 16/8 VM 5 77 15/7 C1 8 major. 2216 16/7 VM 4 15 15/6 C1 7 major. 10001 16/6 VM 3 35 15/5 C1 6 major. 9138 16/5 VM 2 21 15/4 Early Pile up 1 16/4 VM 1 right 5 15/3 H Random Trig 2 16/3 M1 10 left 3 15/2 F pretrigger 8630 16/2 M1 9 15 15/1 VM hole up 565 16/1 M1 8 31 15/0 all events 10001 16/0 M1 7 52 17/15 M1 6 158 18/15 0 17/14 M1 5 0 18/14 0 17/13 M1 4 0 18/13 0 17/12 M1 3 0 18/12 0 17/11 M1 2 2 18/11 0 17/10 M1 1 right 1 18/10 0 17/9 M2 10 left 0 18/9 0 17/8 M2 9 0 18/8 0 17/7 M2 8 0 18/7 0 17/6 M2 7 12 18/6 0 17/5 M2 6 77 18/5 0 17/4 M2 5 12 18/4 0 17/3 M2 4 26 18/3 0 17/2 M2 3 6 18/2 0 17/1 M2 2 0 18/1 0 17/0 M2 1 0 18/0 Late pile up 220 ************************************************* Events with Signal Hits on any MWPC 8383 Effciciency of MWPC 2 is 74.05586 % Effciciency of MWPC 3 is 71.35683 % Effciciency of MWPC 4 is 71.93221 % Effciciency of MWPC 5 is 86.67224 % ************************************************* ************************************************* number of physics triggers = 8421 estimated number of electrons = 1161 estimated number of pions = 7260 NOTE: these numbers only include physics triggers chosen by the shift crew (ie. e pi or mu triggers could be requested) *************************************************