Run8112 Momentum 150 GeV, particle type: 3 CryoX= 100.0 TableY= .0 10001 Events written to file data/run_8112.dat Pattern unit statistics: 15/15 pi/e*C Trig 5932 16/15 VM 12 c low 56 15/14 pi/e Trig 9410 16/14 VM 11 left 1 15/13 S random Tr 441 16/13 VM 10 23 15/12 mu Trig 138 16/12 VM 9 41 15/11 MWPC Trig 0 16/11 VM 8 57 15/10 VM hole low 50 16/10 VM 7 68 15/9 pi/e/mu 0 16/9 VM 6 cent up 15 15/8 0 16/8 VM 5 69 15/7 C1 8 major. 2460 16/7 VM 4 40 15/6 C1 7 major. 10001 16/6 VM 3 41 15/5 C1 6 major. 5950 16/5 VM 2 42 15/4 Early Pile up 52 16/4 VM 1 right 13 15/3 H Random Trig 0 16/3 M1 10 left 45 15/2 F pretrigger 9536 16/2 M1 9 275 15/1 VM hole up 110 16/1 M1 8 463 15/0 all events 10001 16/0 M1 7 843 17/15 M1 6 1114 18/15 0 17/14 M1 5 25 18/14 0 17/13 M1 4 1 18/13 0 17/12 M1 3 6 18/12 0 17/11 M1 2 10 18/11 0 17/10 M1 1 right 7 18/10 0 17/9 M2 10 left 0 18/9 0 17/8 M2 9 0 18/8 0 17/7 M2 8 5 18/7 0 17/6 M2 7 18 18/6 0 17/5 M2 6 184 18/5 0 17/4 M2 5 18 18/4 0 17/3 M2 4 16 18/3 0 17/2 M2 3 10 18/2 0 17/1 M2 2 0 18/1 0 17/0 M2 1 0 18/0 Late pile up 2253 ************************************************* Events with Signal Hits on any MWPC 6694 Effciciency of MWPC 2 is 52.40585 % Effciciency of MWPC 3 is 52.40585 % Effciciency of MWPC 4 is 61.10878 % Effciciency of MWPC 5 is 67.82426 % ************************************************* ************************************************* number of physics triggers = 7205 estimated number of electrons = 410 estimated number of pions = 6795 NOTE: these numbers only include physics triggers chosen by the shift crew (ie. e pi or mu triggers could be requested) *************************************************