Run10967 Sun Jul 15 03:24:16 2001 Momentum 100 GeV, particle type: 1 Xcal=-241.0 Ycal= 88.0 5000 Events written to file data/run_10967.dat Pattern unit statistics: 15/15 pi/e*C Trig 0 16/15 VM 12 c low 1 15/14 pi/e Trig 4986 16/14 VM 11 left 0 15/13 S random Tr 0 16/13 VM 10 0 15/12 mu Trig 0 16/12 VM 9 2 15/11 MWPC Trig 0 16/11 VM 8 1 15/10 VM hole low 5 16/10 VM 7 4 15/9 pi/e/mu 0 16/9 VM 6 cent up 1 15/8 0 16/8 VM 5 4 15/7 C1 8 major. 0 16/7 VM 4 1 15/6 C1 7 major. 1 16/6 VM 3 2 15/5 C1 6 major. 1 16/5 VM 2 0 15/4 Early Pile up 2 16/4 VM 1 right 0 15/3 H Random Trig 0 16/3 M1 10 left 0 15/2 F pretrigger 4995 16/2 M1 9 12 15/1 VM hole up 2 16/1 M1 8 31 15/0 all events 5000 16/0 M1 7 31 17/15 M1 6 150 18/15 0 17/14 M1 5 0 18/14 0 17/13 M1 4 0 18/13 0 17/12 M1 3 1 18/12 0 17/11 M1 2 0 18/11 0 17/10 M1 1 right 0 18/10 0 17/9 M2 10 left 0 18/9 0 17/8 M2 9 0 18/8 0 17/7 M2 8 1 18/7 0 17/6 M2 7 5 18/6 0 17/5 M2 6 926 18/5 0 17/4 M2 5 48 18/4 0 17/3 M2 4 13 18/3 0 17/2 M2 3 8 18/2 0 17/1 M2 2 0 18/1 0 17/0 M2 1 0 18/0 Late pile up 2 ************************************************* Number of signal Hits on any MWPC 24310 Events used to calculate efficiencies 5000 Effciciency of MWPC 2 in X is 89.3 % in Y is 94.0 % Effciciency of MWPC 3 in X is 93.9 % in Y is 87.3 % Effciciency of MWPC 4 in X is 81.7 % in Y is 93.1 % Effciciency of MWPC 5 in X is 93.7 % in Y is 94.3 % ************************************************* ************************************************* number of physics triggers = 4985 estimated number of electrons = 2700 estimated number of pions = 2285 NOTE: these numbers only include physics triggers chosen by the shift crew (ie. e pi or mu triggers could be requested) *************************************************