Run11078 Fri Jul 20 21:13:29 2001 Momentum 180 GeV, particle type: 2 Xcal= -83.0 Ycal= .0 5000 Events written to file data/run_11078.dat Pattern unit statistics: 15/15 pi/e*C Trig 2335 16/15 VM 12 c low 0 15/14 pi/e Trig 3296 16/14 VM 11 left 0 15/13 S random Tr 51 16/13 VM 10 0 15/12 mu Trig 1550 16/12 VM 9 0 15/11 MWPC Trig 0 16/11 VM 8 0 15/10 VM hole low 2 16/10 VM 7 0 15/9 pi/e/mu 0 16/9 VM 6 cent up 0 15/8 0 16/8 VM 5 0 15/7 C1 8 major. 1497 16/7 VM 4 0 15/6 C1 7 major. 2619 16/6 VM 3 0 15/5 C1 6 major. 3631 16/5 VM 2 0 15/4 Early Pile up 1910 16/4 VM 1 right 0 15/3 H Random Trig 0 16/3 M1 10 left 0 15/2 F pretrigger 4847 16/2 M1 9 21 15/1 VM hole up 3 16/1 M1 8 66 15/0 all events 5000 16/0 M1 7 185 17/15 M1 6 1833 18/15 0 17/14 M1 5 7 18/14 0 17/13 M1 4 0 18/13 0 17/12 M1 3 0 18/12 0 17/11 M1 2 0 18/11 0 17/10 M1 1 right 0 18/10 0 17/9 M2 10 left 0 18/9 0 17/8 M2 9 1 18/8 0 17/7 M2 8 10 18/7 0 17/6 M2 7 46 18/6 0 17/5 M2 6 3504 18/5 0 17/4 M2 5 186 18/4 0 17/3 M2 4 65 18/3 0 17/2 M2 3 38 18/2 0 17/1 M2 2 0 18/1 0 17/0 M2 1 0 18/0 Late pile up 0 ************************************************* Number of signal Hits on any MWPC 13735 Events used to calculate efficiencies 4949 Effciciency of MWPC 2 in X is 44.0 % in Y is 47.6 % Effciciency of MWPC 3 in X is 47.7 % in Y is 44.3 % Effciciency of MWPC 4 in X is 37.0 % in Y is 49.0 % Effciciency of MWPC 5 in X is 53.4 % in Y is 53.6 % ************************************************* ************************************************* number of physics triggers = 2936 estimated number of electrons = 180 estimated number of pions = 2756 NOTE: these numbers only include physics triggers chosen by the shift crew (ie. e pi or mu triggers could be requested) *************************************************