Run 9470 Thu Jun 1 08:12:22 2000 Momentum 148 GeV, particle type: 1 Xcal= 138.0 Ycal= .0 5000 Events written to file data/run_9470.dat Pattern unit statistics: 15/15 pi/e*C Trig 17 16/15 VM 12 c low 0 15/14 pi/e Trig 4759 16/14 VM 11 left 0 15/13 S random Tr 222 16/13 VM 10 3 15/12 mu Trig 2 16/12 VM 9 1 15/11 MWPC Trig 0 16/11 VM 8 4 15/10 VM hole low 3 16/10 VM 7 2 15/9 pi/e/mu 4770 16/9 VM 6 cent up 0 15/8 0 16/8 VM 5 2 15/7 C1 8 major. 0 16/7 VM 4 0 15/6 C1 7 major. 393 16/6 VM 3 0 15/5 C1 6 major. 1719 16/5 VM 2 0 15/4 Early Pile up 5 16/4 VM 1 right 0 15/3 H Random Trig 8 16/3 M1 10 left 2 15/2 F pretrigger 4769 16/2 M1 9 20 15/1 VM hole up 3 16/1 M1 8 42 15/0 all events 5000 16/0 M1 7 77 17/15 M1 6 123 18/15 0 17/14 M1 5 6 18/14 0 17/13 M1 4 0 18/13 0 17/12 M1 3 1 18/12 0 17/11 M1 2 0 18/11 0 17/10 M1 1 right 0 18/10 0 17/9 M2 10 left 0 18/9 0 17/8 M2 9 0 18/8 0 17/7 M2 8 0 18/7 0 17/6 M2 7 3 18/6 0 17/5 M2 6 67 18/5 0 17/4 M2 5 10 18/4 0 17/3 M2 4 8 18/3 0 17/2 M2 3 2 18/2 0 17/1 M2 2 0 18/1 0 17/0 M2 1 0 18/0 Late pile up 187 ************************************************* Number of signal Hits on any MWPC 23590 Events used to calculate efficiencies 4770 Effciciency of MWPC 2 in X is 92.7 % in Y is 97.1 % Effciciency of MWPC 3 in X is 97.2 % in Y is 79.1 % Effciciency of MWPC 4 in X is 90.9 % in Y is 91.3 % Effciciency of MWPC 5 in X is 95.8 % in Y is 96.1 % ************************************************* ************************************************* number of physics triggers = 4805 estimated number of electrons = 3493 estimated number of pions = 1312 NOTE: these numbers only include physics triggers chosen by the shift crew (ie. e pi or mu triggers could be requested) *************************************************