Run8149 Momentum 0 GeV, particle type: 0 CryoX= .0 TableY= .0 1000 Events written to file data/run_8149.dat Pattern unit statistics: 15/15 pi/e*C Trig 692 16/15 VM 12 c low 28 15/14 pi/e Trig 46 16/14 VM 11 left 3 15/13 S random Tr 0 16/13 VM 10 7 15/12 mu Trig 0 16/12 VM 9 20 15/11 MWPC Trig 269 16/11 VM 8 33 15/10 VM hole low 143 16/10 VM 7 46 15/9 pi/e/mu 0 16/9 VM 6 cent up 5 15/8 0 16/8 VM 5 47 15/7 C1 8 major. 82 16/7 VM 4 20 15/6 C1 7 major. 1001 16/6 VM 3 28 15/5 C1 6 major. 709 16/5 VM 2 16 15/4 Early Pile up 31 16/4 VM 1 right 9 15/3 H Random Trig 0 16/3 M1 10 left 0 15/2 F pretrigger 750 16/2 M1 9 37 15/1 VM hole up 160 16/1 M1 8 63 15/0 all events 1001 16/0 M1 7 88 17/15 M1 6 128 18/15 0 17/14 M1 5 7 18/14 0 17/13 M1 4 1 18/13 0 17/12 M1 3 1 18/12 0 17/11 M1 2 4 18/11 0 17/10 M1 1 right 2 18/10 0 17/9 M2 10 left 0 18/9 0 17/8 M2 9 0 18/8 0 17/7 M2 8 1 18/7 0 17/6 M2 7 2 18/6 0 17/5 M2 6 9 18/5 0 17/4 M2 5 3 18/4 0 17/3 M2 4 1 18/3 0 17/2 M2 3 1 18/2 0 17/1 M2 2 0 18/1 38 17/0 M2 1 0 18/0 Late pile up 650 ************************************************* Events with Signal Hits on any MWPC 4335 Effciciency of MWPC 2 in X is 65.0 % in Y is 74.5 % Effciciency of MWPC 3 in X is 77.8 % in Y is 59.5 % Effciciency of MWPC 4 in X is 57.8 % in Y is 56.9 % Effciciency of MWPC 5 in X is 77.6 % in Y is 80.5 % ************************************************* ************************************************* number of physics triggers = 254 estimated number of electrons = 38 estimated number of pions = 216 NOTE: these numbers only include physics triggers chosen by the shift crew (ie. e pi or mu triggers could be requested) *************************************************