Run8196 Momentum 119 GeV, particle type: 1 CryoX=-232.0 TableY= 149.0 10000 Events written to file data/run_8196.dat Pattern unit statistics: 15/15 pi/e*C Trig 9443 16/15 VM 12 c low 19 15/14 pi/e Trig 55 16/14 VM 11 left 0 15/13 S random Tr 427 16/13 VM 10 3 15/12 mu Trig 0 16/12 VM 9 8 15/11 MWPC Trig 139 16/11 VM 8 15 15/10 VM hole low 93 16/10 VM 7 36 15/9 pi/e/mu 0 16/9 VM 6 cent up 11 15/8 0 16/8 VM 5 33 15/7 C1 8 major. 2 16/7 VM 4 10 15/6 C1 7 major. 10001 16/6 VM 3 15 15/5 C1 6 major. 9503 16/5 VM 2 5 15/4 Early Pile up 18 16/4 VM 1 right 7 15/3 H Random Trig 1 16/3 M1 10 left 3 15/2 F pretrigger 9488 16/2 M1 9 79 15/1 VM hole up 106 16/1 M1 8 153 15/0 all events 10001 16/0 M1 7 234 17/15 M1 6 338 18/15 0 17/14 M1 5 5 18/14 0 17/13 M1 4 0 18/13 0 17/12 M1 3 3 18/12 0 17/11 M1 2 0 18/11 0 17/10 M1 1 right 1 18/10 0 17/9 M2 10 left 0 18/9 0 17/8 M2 9 0 18/8 0 17/7 M2 8 2 18/7 0 17/6 M2 7 6 18/6 0 17/5 M2 6 55 18/5 0 17/4 M2 5 2 18/4 0 17/3 M2 4 8 18/3 0 17/2 M2 3 14 18/2 0 17/1 M2 2 0 18/1 5 17/0 M2 1 0 18/0 Late pile up 2230 ************************************************* Number of signal Hits on any MWPC 46355 Events used to calculate efficiencies 9573 Effciciency of MWPC 2 in X is 83.5 % in Y is 91.7 % Effciciency of MWPC 3 in X is 75.9 % in Y is 81.4 % Effciciency of MWPC 4 in X is 85.0 % in Y is 81.8 % Effciciency of MWPC 5 in X is 94.2 % in Y is 94.6 % ************************************************* ************************************************* number of physics triggers = 7229 estimated number of electrons = 4172 estimated number of pions = 3057 NOTE: these numbers only include physics triggers chosen by the shift crew (ie. e pi or mu triggers could be requested) *************************************************