Run8206 Momentum 120 GeV, particle type: 3 CryoX= .0 TableY= .0 10000 Events written to file data/run_8206.dat Pattern unit statistics: 15/15 pi/e*C Trig 9415 16/15 VM 12 c low 14 15/14 pi/e Trig 79 16/14 VM 11 left 1 15/13 S random Tr 433 16/13 VM 10 5 15/12 mu Trig 0 16/12 VM 9 5 15/11 MWPC Trig 121 16/11 VM 8 9 15/10 VM hole low 25 16/10 VM 7 16 15/9 pi/e/mu 0 16/9 VM 6 cent up 1 15/8 0 16/8 VM 5 12 15/7 C1 8 major. 3 16/7 VM 4 10 15/6 C1 7 major. 10001 16/6 VM 3 9 15/5 C1 6 major. 9440 16/5 VM 2 8 15/4 Early Pile up 11 16/4 VM 1 right 5 15/3 H Random Trig 21 16/3 M1 10 left 1 15/2 F pretrigger 9481 16/2 M1 9 218 15/1 VM hole up 31 16/1 M1 8 369 15/0 all events 10001 16/0 M1 7 614 17/15 M1 6 744 18/15 0 17/14 M1 5 19 18/14 0 17/13 M1 4 4 18/13 0 17/12 M1 3 3 18/12 0 17/11 M1 2 0 18/11 0 17/10 M1 1 right 2 18/10 0 17/9 M2 10 left 0 18/9 0 17/8 M2 9 0 18/8 0 17/7 M2 8 5 18/7 0 17/6 M2 7 8 18/6 0 17/5 M2 6 51 18/5 0 17/4 M2 5 7 18/4 0 17/3 M2 4 14 18/3 0 17/2 M2 3 5 18/2 0 17/1 M2 2 0 18/1 7 17/0 M2 1 0 18/0 Late pile up 1737 ************************************************* Number of signal Hits on any MWPC 50 Events used to calculate efficiencies 9547 Effciciency of MWPC 2 in X is .0 % in Y is .0 % Effciciency of MWPC 3 in X is .1 % in Y is .0 % Effciciency of MWPC 4 in X is .0 % in Y is .0 % Effciciency of MWPC 5 in X is .0 % in Y is .0 % ************************************************* ************************************************* number of physics triggers = 7737 estimated number of electrons = 601 estimated number of pions = 7136 NOTE: these numbers only include physics triggers chosen by the shift crew (ie. e pi or mu triggers could be requested) *************************************************