Run8486 Momentum 150 GeV, particle type: 3 CryoX= 190.0 TableY= 134.0 10000 Events written to file data/run_8486.dat Pattern unit statistics: 15/15 pi/e*C Trig 3379 16/15 VM 12 c low 1 15/14 pi/e Trig 9505 16/14 VM 11 left 0 15/13 S random Tr 449 16/13 VM 10 0 15/12 mu Trig 0 16/12 VM 9 0 15/11 MWPC Trig 0 16/11 VM 8 0 15/10 VM hole low 1 16/10 VM 7 0 15/9 pi/e/mu 0 16/9 VM 6 cent up 0 15/8 0 16/8 VM 5 0 15/7 C1 8 major. 1384 16/7 VM 4 0 15/6 C1 7 major. 2808 16/6 VM 3 1 15/5 C1 6 major. 3380 16/5 VM 2 2 15/4 Early Pile up 3 16/4 VM 1 right 0 15/3 H Random Trig 44 16/3 M1 10 left 16 15/2 F pretrigger 9506 16/2 M1 9 274 15/1 VM hole up 4 16/1 M1 8 479 15/0 all events 10001 16/0 M1 7 802 17/15 M1 6 1093 18/15 0 17/14 M1 5 43 18/14 0 17/13 M1 4 2 18/13 0 17/12 M1 3 4 18/12 0 17/11 M1 2 2 18/11 0 17/10 M1 1 right 5 18/10 0 17/9 M2 10 left 0 18/9 0 17/8 M2 9 0 18/8 0 17/7 M2 8 1 18/7 0 17/6 M2 7 2 18/6 0 17/5 M2 6 22 18/5 0 17/4 M2 5 1 18/4 0 17/3 M2 4 12 18/3 0 17/2 M2 3 7 18/2 0 17/1 M2 2 0 18/1 0 17/0 M2 1 0 18/0 Late pile up 203 ************************************************* Number of signal Hits on any MWPC 47295 Events used to calculate efficiencies 9508 Effciciency of MWPC 2 in X is 75.7 % in Y is 88.0 % Effciciency of MWPC 3 in X is 88.7 % in Y is 80.5 % Effciciency of MWPC 4 in X is 80.1 % in Y is 89.4 % Effciciency of MWPC 5 in X is 95.8 % in Y is 95.9 % ************************************************* ************************************************* number of physics triggers = 9292 estimated number of electrons = 866 estimated number of pions = 8426 NOTE: these numbers only include physics triggers chosen by the shift crew (ie. e pi or mu triggers could be requested) *************************************************