Run8559 Momentum 150 GeV, particle type: 3 CryoX= 80.0 TableY= -60.0 10000 Events written to file data/run_8559.dat Pattern unit statistics: 15/15 pi/e*C Trig 2935 16/15 VM 12 c low 3 15/14 pi/e Trig 9522 16/14 VM 11 left 0 15/13 S random Tr 460 16/13 VM 10 0 15/12 mu Trig 0 16/12 VM 9 0 15/11 MWPC Trig 0 16/11 VM 8 1 15/10 VM hole low 1 16/10 VM 7 2 15/9 pi/e/mu 0 16/9 VM 6 cent up 0 15/8 0 16/8 VM 5 1 15/7 C1 8 major. 178 16/7 VM 4 0 15/6 C1 7 major. 1753 16/6 VM 3 0 15/5 C1 6 major. 2938 16/5 VM 2 0 15/4 Early Pile up 4 16/4 VM 1 right 0 15/3 H Random Trig 13 16/3 M1 10 left 14 15/2 F pretrigger 9527 16/2 M1 9 284 15/1 VM hole up 1 16/1 M1 8 441 15/0 all events 10001 16/0 M1 7 760 17/15 M1 6 985 18/15 0 17/14 M1 5 24 18/14 0 17/13 M1 4 4 18/13 0 17/12 M1 3 9 18/12 0 17/11 M1 2 1 18/11 0 17/10 M1 1 right 0 18/10 0 17/9 M2 10 left 0 18/9 0 17/8 M2 9 0 18/8 0 17/7 M2 8 1 18/7 0 17/6 M2 7 3 18/6 0 17/5 M2 6 40 18/5 0 17/4 M2 5 4 18/4 0 17/3 M2 4 15 18/3 0 17/2 M2 3 8 18/2 0 17/1 M2 2 0 18/1 0 17/0 M2 1 0 18/0 Late pile up 218 ************************************************* Number of signal Hits on any MWPC 47510 Events used to calculate efficiencies 9528 Effciciency of MWPC 2 in X is 85.3 % in Y is 94.0 % Effciciency of MWPC 3 in X is 94.8 % in Y is 68.3 % Effciciency of MWPC 4 in X is 85.6 % in Y is 81.8 % Effciciency of MWPC 5 in X is 97.8 % in Y is 97.6 % ************************************************* ************************************************* number of physics triggers = 9302 estimated number of electrons = 644 estimated number of pions = 8658 NOTE: these numbers only include physics triggers chosen by the shift crew (ie. e pi or mu triggers could be requested) *************************************************