Run8614 Momentum 150 GeV, particle type: 1 CryoX= -87.0 TableY= -45.0 5000 Events written to file data/run_8614.dat Pattern unit statistics: 15/15 pi/e*C Trig 2832 16/15 VM 12 c low 4 15/14 pi/e Trig 4754 16/14 VM 11 left 0 15/13 S random Tr 230 16/13 VM 10 0 15/12 mu Trig 0 16/12 VM 9 2 15/11 MWPC Trig 0 16/11 VM 8 4 15/10 VM hole low 8 16/10 VM 7 3 15/9 pi/e/mu 0 16/9 VM 6 cent up 1 15/8 0 16/8 VM 5 3 15/7 C1 8 major. 305 16/7 VM 4 0 15/6 C1 7 major. 1820 16/6 VM 3 2 15/5 C1 6 major. 2839 16/5 VM 2 3 15/4 Early Pile up 5 16/4 VM 1 right 1 15/3 H Random Trig 8 16/3 M1 10 left 4 15/2 F pretrigger 4758 16/2 M1 9 65 15/1 VM hole up 11 16/1 M1 8 139 15/0 all events 5001 16/0 M1 7 188 17/15 M1 6 293 18/15 0 17/14 M1 5 6 18/14 0 17/13 M1 4 2 18/13 0 17/12 M1 3 2 18/12 0 17/11 M1 2 0 18/11 0 17/10 M1 1 right 0 18/10 0 17/9 M2 10 left 0 18/9 0 17/8 M2 9 0 18/8 0 17/7 M2 8 2 18/7 0 17/6 M2 7 1 18/6 0 17/5 M2 6 128 18/5 0 17/4 M2 5 6 18/4 0 17/3 M2 4 11 18/3 0 17/2 M2 3 6 18/2 0 17/1 M2 2 0 18/1 0 17/0 M2 1 0 18/0 Late pile up 280 ************************************************* Number of signal Hits on any MWPC 23275 Events used to calculate efficiencies 4763 Effciciency of MWPC 2 in X is 88.1 % in Y is 94.1 % Effciciency of MWPC 3 in X is 94.0 % in Y is 97.7 % Effciciency of MWPC 4 in X is 88.7 % in Y is 89.6 % Effciciency of MWPC 5 in X is 95.4 % in Y is 95.2 % ************************************************* ************************************************* number of physics triggers = 4467 estimated number of electrons = 2226 estimated number of pions = 2241 NOTE: these numbers only include physics triggers chosen by the shift crew (ie. e pi or mu triggers could be requested) *************************************************