Run8622 Momentum 119 GeV, particle type: 1 CryoX= -80.0 TableY= .0 5000 Events written to file data/run_8622.dat Pattern unit statistics: 15/15 pi/e*C Trig 2801 16/15 VM 12 c low 1378 15/14 pi/e Trig 4575 16/14 VM 11 left 2 15/13 S random Tr 223 16/13 VM 10 113 15/12 mu Trig 0 16/12 VM 9 410 15/11 MWPC Trig 0 16/11 VM 8 1073 15/10 VM hole low 2062 16/10 VM 7 1801 15/9 pi/e/mu 0 16/9 VM 6 cent up 17 15/8 0 16/8 VM 5 1922 15/7 C1 8 major. 275 16/7 VM 4 296 15/6 C1 7 major. 1734 16/6 VM 3 525 15/5 C1 6 major. 2822 16/5 VM 2 343 15/4 Early Pile up 630 16/4 VM 1 right 95 15/3 H Random Trig 134 16/3 M1 10 left 0 15/2 F pretrigger 4577 16/2 M1 9 49 15/1 VM hole up 2212 16/1 M1 8 75 15/0 all events 5001 16/0 M1 7 126 17/15 M1 6 446 18/15 0 17/14 M1 5 4 18/14 0 17/13 M1 4 0 18/13 0 17/12 M1 3 0 18/12 0 17/11 M1 2 0 18/11 0 17/10 M1 1 right 0 18/10 0 17/9 M2 10 left 0 18/9 0 17/8 M2 9 0 18/8 0 17/7 M2 8 9 18/7 0 17/6 M2 7 8 18/6 0 17/5 M2 6 699 18/5 0 17/4 M2 5 81 18/4 0 17/3 M2 4 14 18/3 0 17/2 M2 3 13 18/2 0 17/1 M2 2 0 18/1 9 17/0 M2 1 0 18/0 Late pile up 931 ************************************************* Number of signal Hits on any MWPC 655 Events used to calculate efficiencies 4644 Effciciency of MWPC 2 in X is 2.4 % in Y is 2.7 % Effciciency of MWPC 3 in X is 2.6 % in Y is 2.8 % Effciciency of MWPC 4 in X is 2.5 % in Y is 2.5 % Effciciency of MWPC 5 in X is 2.7 % in Y is 2.7 % ************************************************* ************************************************* number of physics triggers = 1849 estimated number of electrons = 338 estimated number of pions = 1511 NOTE: these numbers only include physics triggers chosen by the shift crew (ie. e pi or mu triggers could be requested) *************************************************