Run8702 Momentum 80 GeV, particle type: 1 CryoX= 78.0 TableY= 140.0 10000 Events written to file data/run_8702.dat Pattern unit statistics: 15/15 pi/e*C Trig 7079 16/15 VM 12 c low 6 15/14 pi/e Trig 9502 16/14 VM 11 left 0 15/13 S random Tr 441 16/13 VM 10 1 15/12 mu Trig 38 16/12 VM 9 5 15/11 MWPC Trig 0 16/11 VM 8 7 15/10 VM hole low 29 16/10 VM 7 12 15/9 pi/e/mu 9536 16/9 VM 6 cent up 1 15/8 0 16/8 VM 5 14 15/7 C1 8 major. 810 16/7 VM 4 2 15/6 C1 7 major. 4437 16/6 VM 3 7 15/5 C1 6 major. 7110 16/5 VM 2 7 15/4 Early Pile up 13 16/4 VM 1 right 2 15/3 H Random Trig 15 16/3 M1 10 left 0 15/2 F pretrigger 9534 16/2 M1 9 2 15/1 VM hole up 32 16/1 M1 8 11 15/0 all events 10001 16/0 M1 7 17 17/15 M1 6 221 18/15 0 17/14 M1 5 2 18/14 0 17/13 M1 4 0 18/13 0 17/12 M1 3 0 18/12 0 17/11 M1 2 0 18/11 0 17/10 M1 1 right 0 18/10 0 17/9 M2 10 left 0 18/9 0 17/8 M2 9 1 18/8 0 17/7 M2 8 1 18/7 0 17/6 M2 7 5 18/6 0 17/5 M2 6 337 18/5 0 17/4 M2 5 39 18/4 0 17/3 M2 4 14 18/3 0 17/2 M2 3 11 18/2 0 17/1 M2 2 0 18/1 0 17/0 M2 1 0 18/0 Late pile up 814 ************************************************* Number of signal Hits on any MWPC 45355 Events used to calculate efficiencies 9545 Effciciency of MWPC 2 in X is 83.5 % in Y is 90.2 % Effciciency of MWPC 3 in X is 95.0 % in Y is 81.8 % Effciciency of MWPC 4 in X is 83.4 % in Y is 84.5 % Effciciency of MWPC 5 in X is 92.6 % in Y is 92.7 % ************************************************* ************************************************* number of physics triggers = 8685 estimated number of electrons = 6732 estimated number of pions = 1953 NOTE: these numbers only include physics triggers chosen by the shift crew (ie. e pi or mu triggers could be requested) *************************************************