Run9004 Momentum 10 GeV, particle type: 3 Xcal= 80.0 Ycal= .0 20000 Events written to file data/run_9004.dat Pattern unit statistics: 15/15 pi/e*C Trig 18738 16/15 VM 12 c low 24 15/14 pi/e Trig 328 16/14 VM 11 left 0 15/13 S random Tr 904 16/13 VM 10 6 15/12 mu Trig 0 16/12 VM 9 10 15/11 MWPC Trig 0 16/11 VM 8 27 15/10 VM hole low 77 16/10 VM 7 44 15/9 pi/e/mu 18889 16/9 VM 6 cent up 0 15/8 0 16/8 VM 5 34 15/7 C1 8 major. 4569 16/7 VM 4 5 15/6 C1 7 major. 12647 16/6 VM 3 11 15/5 C1 6 major. 18758 16/5 VM 2 11 15/4 Early Pile up 67 16/4 VM 1 right 4 15/3 H Random Trig 143 16/3 M1 10 left 2 15/2 F pretrigger 18855 16/2 M1 9 10 15/1 VM hole up 116 16/1 M1 8 14 15/0 all events 20001 16/0 M1 7 27 17/15 M1 6 98 18/15 0 17/14 M1 5 0 18/14 0 17/13 M1 4 0 18/13 0 17/12 M1 3 0 18/12 0 17/11 M1 2 0 18/11 0 17/10 M1 1 right 0 18/10 0 17/9 M2 10 left 0 18/9 0 17/8 M2 9 0 18/8 0 17/7 M2 8 3 18/7 0 17/6 M2 7 28 18/6 0 17/5 M2 6 102 18/5 0 17/4 M2 5 10 18/4 0 17/3 M2 4 65 18/3 0 17/2 M2 3 19 18/2 0 17/1 M2 2 0 18/1 3 17/0 M2 1 0 18/0 Late pile up 4991 ************************************************* Number of signal Hits on any MWPC 60315 Events used to calculate efficiencies 18954 Effciciency of MWPC 2 in X is 51.3 % in Y is 58.6 % Effciciency of MWPC 3 in X is 59.4 % in Y is 41.1 % Effciciency of MWPC 4 in X is 53.5 % in Y is 55.6 % Effciciency of MWPC 5 in X is 61.0 % in Y is 60.9 % ************************************************* ************************************************* number of physics triggers = 13847 estimated number of electrons = 1538 estimated number of pions = 12309 NOTE: these numbers only include physics triggers chosen by the shift crew (ie. e pi or mu triggers could be requested) *************************************************