Run9117 Momentum 20 GeV, particle type: 1 Xcal= 232.0 Ycal= 120.0 10000 Events written to file data/run_9117.dat Pattern unit statistics: 15/15 pi/e*C Trig 9053 16/15 VM 12 c low 3 15/14 pi/e Trig 444 16/14 VM 11 left 0 15/13 S random Tr 444 16/13 VM 10 0 15/12 mu Trig 0 16/12 VM 9 0 15/11 MWPC Trig 0 16/11 VM 8 5 15/10 VM hole low 15 16/10 VM 7 6 15/9 pi/e/mu 9434 16/9 VM 6 cent up 0 15/8 0 16/8 VM 5 5 15/7 C1 8 major. 3446 16/7 VM 4 2 15/6 C1 7 major. 7757 16/6 VM 3 4 15/5 C1 6 major. 9057 16/5 VM 2 2 15/4 Early Pile up 13 16/4 VM 1 right 1 15/3 H Random Trig 116 16/3 M1 10 left 0 15/2 F pretrigger 9432 16/2 M1 9 2 15/1 VM hole up 21 16/1 M1 8 3 15/0 all events 10001 16/0 M1 7 3 17/15 M1 6 9 18/15 0 17/14 M1 5 0 18/14 0 17/13 M1 4 0 18/13 0 17/12 M1 3 0 18/12 0 17/11 M1 2 0 18/11 0 17/10 M1 1 right 0 18/10 0 17/9 M2 10 left 0 18/9 0 17/8 M2 9 0 18/8 0 17/7 M2 8 1 18/7 0 17/6 M2 7 0 18/6 0 17/5 M2 6 13 18/5 0 17/4 M2 5 2 18/4 0 17/3 M2 4 12 18/3 0 17/2 M2 3 3 18/2 0 17/1 M2 2 0 18/1 1 17/0 M2 1 0 18/0 Late pile up 293 ************************************************* Number of signal Hits on any MWPC 43840 Events used to calculate efficiencies 9441 Effciciency of MWPC 2 in X is 80.2 % in Y is 88.0 % Effciciency of MWPC 3 in X is 89.0 % in Y is 83.6 % Effciciency of MWPC 4 in X is 81.6 % in Y is 85.6 % Effciciency of MWPC 5 in X is 91.0 % in Y is 91.1 % ************************************************* ************************************************* number of physics triggers = 9126 estimated number of electrons = 4288 estimated number of pions = 4838 NOTE: these numbers only include physics triggers chosen by the shift crew (ie. e pi or mu triggers could be requested) *************************************************