Run9304 Momentum 193 GeV, particle type: 1 Xcal=-232.0 Ycal=-140.0 6000 Events written to file data/run_9304.dat Pattern unit statistics: 15/15 pi/e*C Trig 5562 16/15 VM 12 c low 2 15/14 pi/e Trig 48 16/14 VM 11 left 0 15/13 S random Tr 261 16/13 VM 10 0 15/12 mu Trig 4 16/12 VM 9 0 15/11 MWPC Trig 0 16/11 VM 8 0 15/10 VM hole low 0 16/10 VM 7 1 15/9 pi/e/mu 5575 16/9 VM 6 cent up 0 15/8 0 16/8 VM 5 1 15/7 C1 8 major. 1556 16/7 VM 4 0 15/6 C1 7 major. 4186 16/6 VM 3 0 15/5 C1 6 major. 5565 16/5 VM 2 0 15/4 Early Pile up 2 16/4 VM 1 right 1 15/3 H Random Trig 164 16/3 M1 10 left 0 15/2 F pretrigger 5575 16/2 M1 9 23 15/1 VM hole up 4 16/1 M1 8 25 15/0 all events 6001 16/0 M1 7 41 17/15 M1 6 159 18/15 0 17/14 M1 5 1 18/14 0 17/13 M1 4 0 18/13 0 17/12 M1 3 0 18/12 0 17/11 M1 2 0 18/11 0 17/10 M1 1 right 0 18/10 0 17/9 M2 10 left 0 18/9 0 17/8 M2 9 0 18/8 0 17/7 M2 8 1 18/7 0 17/6 M2 7 7 18/6 0 17/5 M2 6 636 18/5 0 17/4 M2 5 28 18/4 0 17/3 M2 4 9 18/3 0 17/2 M2 3 6 18/2 0 17/1 M2 2 0 18/1 0 17/0 M2 1 0 18/0 Late pile up 27 ************************************************* Number of signal Hits on any MWPC 26715 Events used to calculate efficiencies 5576 Effciciency of MWPC 2 in X is 84.0 % in Y is 91.2 % Effciciency of MWPC 3 in X is 92.1 % in Y is 83.9 % Effciciency of MWPC 4 in X is 84.9 % in Y is 92.9 % Effciciency of MWPC 5 in X is 94.5 % in Y is 94.3 % ************************************************* ************************************************* number of physics triggers = 5542 estimated number of electrons = 4145 estimated number of pions = 1397 NOTE: these numbers only include physics triggers chosen by the shift crew (ie. e pi or mu triggers could be requested) *************************************************