D reconstruction
Kenji Hamano
Last modified : Aug 22, 2005
Back to Home
Back to privious page
The following requirements were missing (loosened) in BToDlnu skims
1. Kaon to produce D0 list
KMicroNotPion was used as a imput list of kaon, but it was loosened to GTL in skim.
Note that KMicroNotPionGTL was used to produce Dch.
2. D vertex condition
Daughters of D (a kaon and a few Pions) come from a point.
3. p*D cut
D momentum in the CM frame satisfies, 0.5 < p*D < 2.5 GeV
I applied only KMicroNotPion requrement to suppress background
Run4 was used. Luminosities are approximately 25 fb-1
Bhabha veto is applied.
1. BToDlnu skims
D mass : K list = GTL
D mass : K list = KMicroNotPion
A. D0Kpi
D0 mass (D0->Kpi) : MC components
D0 mass (D0->Kpi) : MC components - B and Other separated
Fractional uncertainty of signal
Delta_S / S = sqrt[(nSig + nBkg + rho*rho*nBkg*nBkg)] / (nSig)
Setting rho = 0
Only D mass peak region: 1.845 GeV < D mass < 1.885 GeV
K list = GTL case:
nSig = 507553, nBkg = 747267, Delta_S/S = 2.2e-3
K list = KMicroNotPion case:
nSig = 378510, nBkg = 519317, Delta_S/S = 2.5e-3
Tighter D mass peak region: 1.855 GeV < D mass < 1.875 GeV
K list = GTL case:
nSig = 322267, nBkg = 408744, Delta_S/S = 2.653e-3
K list = KMicroNotPion case:
nSig = 254931, nBkg = 293909, Delta_S/S = 2.906e-3
B. DchKpipi
Dch mass (Dch->Kpipi) : MC components - B and Other separated
Fractional uncertainty of signal
Only D mass peak region: 1.849 < D mass < 1.889
K list = KMicroNotPionGTL case:
nSig = 806650, nBkg = 864924, Delta_S/S = 1.603e-3
K list = KMicroNotPionGTL + KMicroNotPion case:
nSig = 805798, nBkg = 871547, Delta_S/S = 1.607e-3
Tighter D mass peak region: 1.859 < D mass < 1.879
K list = KMicroNotPionGTL case:
nSig = 446023, nBkg = 459368, Delta_S/S = 2.133e-3
K list = KMicroNotPionGTL + KMicroNotPion case:
nSig = 448767, nBkg = 464479, Delta_S/S = 2.129e-3
2. AddLepton subskims
A. D0Kpi
No tag-lepton momemtum cut
D0 mass (D0->Kpi) : K list = GTL
D0 mass (D0->Kpi) : K list = KMicroNotPion
Tag-lepton momemtum cut dependence
D0 mass (D0->Kpi) P_lep cut dependence : K list = GTL
D0 mass (D0->Kpi) P_lep cut dependence : K list = KMicroNotPion
Fractional uncertainty of signal
Only D mass peak region: 1.849 < D mass < 1.889
K list = GTL case:
nSig = , nBkg = , Delta_S/S =
K list = KMicroNotPion case:
nSig = 144017, nBkg = 181401, Delta_S/S = 3.961e-3
Tighter D mass peak region: 1.855 GeV < D mass < 1.875 GeV
K list = GTL case:
nSig = , nBkg = , Delta_S/S = e-3
K list = KMicroNotPion case:
nSig = 95322, nBkg = 101350, Delta_S/S = 4.65241e-3
B. DchKpipi
Tighter D mass peak region: 1.859 < D mass < 1.879
K list = KMicroNotPionGTL case:
nSig = , nBkg = , Delta_S/S = e-3
K list = KMicroNotPionGTL + KMicroNotPion case:
nSig = 158001, nBkg = 165098, Delta_S/S = 3.59756e-3